Forearm Skin Tissue Dielectric Constant: Effect of Changes in Vascular Volume and Skin Blood Perfusion

Format

Event

Start Date

10-2-2012 12:00 AM

Abstract

Objective. To determine vascular volume (VV) and skin blood perfusion (SBF) effects on skin tissue dielectric constants (TDC). Background. Measuring TDC via the open-ended coaxial probe 300Mz method is a useful non-invasive measure of local skin tissue water but VV and SBF effects on TDC is unknown. Methods. At a depth of 1.5mm TDC and SBF (laser-Doppler-Flowmetry) were measured on forearms of 20 subjects under two test conditions. Test 1 was done with the arm horizontal and then raised. Test 2 was done with the arm horizontal with and without a 50 mmHg cuff compression. Results. For Test 1, horizontal TDC values of 28.7±2.9 decreased slightly but significantly on arm raising to 27.8±2.5, p < 0.01. For Test 2, TDC values of 28.2±2.8 increased slightly but significantly to 29.2±3.1, p < 0.01 during upper arm compression. At the forearm site SBF significantly increased during Test 1 maneuver (+102.6±156%, p < 0.001 and decreased during Test 2 maneuver (-39.5±13.1%, p < 0.001). Conclusion. Over the wide range of VV and SBF shifts used there was only a 3.0-3.5% change in TDC values. This suggests that for most clinical evaluation and tracking purposes the confounding effects of variations in SBF or volume are inconsequential. From the physiological perspective, the decrease in TDC with arm raising is consistent with a gravity-dependent drainage in vascular volume and the increase in TDC with application of cuff pressure is consistent with reduced drainage from vascular compression. The increase in forearm SBF agrees with previous work suggesting that venous emptying leads to arteriolar vasodilation.

This document is currently not available here.

COinS
 
Feb 10th, 12:00 AM

Forearm Skin Tissue Dielectric Constant: Effect of Changes in Vascular Volume and Skin Blood Perfusion

Objective. To determine vascular volume (VV) and skin blood perfusion (SBF) effects on skin tissue dielectric constants (TDC). Background. Measuring TDC via the open-ended coaxial probe 300Mz method is a useful non-invasive measure of local skin tissue water but VV and SBF effects on TDC is unknown. Methods. At a depth of 1.5mm TDC and SBF (laser-Doppler-Flowmetry) were measured on forearms of 20 subjects under two test conditions. Test 1 was done with the arm horizontal and then raised. Test 2 was done with the arm horizontal with and without a 50 mmHg cuff compression. Results. For Test 1, horizontal TDC values of 28.7±2.9 decreased slightly but significantly on arm raising to 27.8±2.5, p < 0.01. For Test 2, TDC values of 28.2±2.8 increased slightly but significantly to 29.2±3.1, p < 0.01 during upper arm compression. At the forearm site SBF significantly increased during Test 1 maneuver (+102.6±156%, p < 0.001 and decreased during Test 2 maneuver (-39.5±13.1%, p < 0.001). Conclusion. Over the wide range of VV and SBF shifts used there was only a 3.0-3.5% change in TDC values. This suggests that for most clinical evaluation and tracking purposes the confounding effects of variations in SBF or volume are inconsequential. From the physiological perspective, the decrease in TDC with arm raising is consistent with a gravity-dependent drainage in vascular volume and the increase in TDC with application of cuff pressure is consistent with reduced drainage from vascular compression. The increase in forearm SBF agrees with previous work suggesting that venous emptying leads to arteriolar vasodilation.