Student Theses, Dissertations and Capstones

Document Type

Thesis - NSU Access Only

Degree Name

Master of Science (M.S.) in Dentistry

Copyright Statement

All rights reserved. This publication is intended for use solely by faculty, students, and staff of Nova Southeastern University. No part of this publication may be reproduced, distributed, or transmitted in any form or by any means, now known or later developed, including but not limited to photocopying, recording, or other electronic or mechanical methods, without the prior written permission of the author or the publisher.

Department

College of Dental Medicine

First Advisor

Evren Kilinc

Second Advisor

Rogerio Armando

Date of original Performance / Presentation

January 2019

Publication Date / Copyright Date

1-1-2019

Abstract

Introduction: Increasing patient demands have driven multiple Clear Aligner Therapy Systems(CATS) to be used for various ranges of malocclusion, including the complex severe crowding cases. Severity level may pose a challenge in CATS especially if the treatment is digitally designed by the software without any orthodontist involvement. There is limited data on the assessment of CAT software’s automatic simulation treatment for orthodontic treatment outcomes. The aim of this study was to evaluate the predicted post-treatment digital models of mild, moderate and severe crowding cases created using CAT software’s default treatment simulation. Pre-treatment models were compared with the digital proposals for various factors such as the maintenance of mandibular dental arch form, inter-canine(ICD)-intermolar(IMD) distances, occlusion, overjet, overbite, and Curve of Spee. Methods: Pretreatment study models of 54 patients(age 13–25; Class I malocclusion; mild, moderate and severe crowding, n=18) were randomly selected and scanned using ATOS scanBox lab scanner. All cases were digitally treated using uLab software’s full-arch-automatic set-up default treatment simulation function with no modifications. Digital pretreatment and predicted post-treatment ICDs and occlusal parameters were measured and statistically analyzed(paired t-test, regression, pairwise comparisons, p<0.05). Results: In predicted post-treatment models, ICD increases(38.9%) and decreases(46.3%) were not significant(0.6mm) in any crowding severity groups(p>0.05). The overbite and number of heavy-occlusal-contacts significantly increased (64.8%, 88.9%, respectively) while the overjet and curve of Spee significantly decreased(67.9%, 64.8%, respectively) in the observations(p<0.05). Majority of the mandibular teeth experienced buccal axial inclination(91.7%) and buccal linear protrusion(66.7%). Conclusions: CAT software’s default simulation treatment without orthodontist involvement could successfully maintain the desired ICD for post-treatment stability in various crowding severities. However, the periodontal health and stability could be jeopardized by tooth movement unsupervised by clinicians, suggesting that allowing CAT software to simulate treatment solely based on artificial intelligence will not allow for proper and healthy occlusal and periodontal relationships.

Disciplines

Dentistry

Keywords

Clear Aligner Therapy; Clear Aligners; Inter-canine distance; Occlusal Contacts; Occlusion; Orthodontics

Files

Download

Download Full Text (19.6 MB)

Files over 10MB may be slow to open. For best results, right-click and select "Save as..."

To access this thesis/dissertation you must have a valid nova.edu OR mynsu.nova.edu email address and create an account for NSUWorks.

Free My Thesis

If you are the author of this work and would like to grant permission to make it openly accessible to all, please click the Free My Thesis button.

  Contact Author

Share

 
COinS