Student Theses, Dissertations and Capstones
Document Type
Thesis - NSU Access Only
Degree Name
Master of Science (M.S.) in Dentistry
Copyright Statement
All rights reserved. This publication is intended for use solely by faculty, students, and staff of Nova Southeastern University. No part of this publication may be reproduced, distributed, or transmitted in any form or by any means, now known or later developed, including but not limited to photocopying, recording, or other electronic or mechanical methods, without the prior written permission of the author or the publisher.
Department
College of Dental Medicine
First Advisor
Theofilos Koutouzis
Date of original Performance / Presentation
January 2021
Publication Date / Copyright Date
1-1-2021
NSUWorks Citation
Mohammed AlRubaie. 2021. THE INFLUENCE OF ABUTMENT MACRO-DESIGN ON PERI-IMPLANT TISSUE DIMENSIONS FOR GUIDED PLACED AND RESTORED IMPLANTS: A 3-YEAR RANDOMIZED CONTROLLED TRIAL.. Master's thesis. Nova Southeastern University. Retrieved from NSUWorks, College of Dental Medicine. (145)
https://nsuworks.nova.edu/hpd_cdm_stuetd/145.
Abstract
Introduction: For optimal dental implant esthetics, the transition of a circumferential implant platform to a proper cervical anatomy has been emphasized. This transition is facilitated by the macro-design of the transmucosal portion of the abutment-restoration complex at the provisional and final stages of implant prosthetic therapy. There is limited information from human studies assessing the impact of abutment macro-design on peri-implant tissue dimensional changes. Aim: The aim of this work was to evaluate the peri-implant tissue levels over a 3-year period for implants connected to either convex or concave final abutments at the time of implant placement. Methods: Twenty-eight patients with one missing maxillary premolar were randomly allocated to receive one single implant with abutments of different emergence shape configuration. Patients of the CX Group had abutments with convex emergence shape and patients of the CV Group had abutments with concave emergence shape. Clinical and radiographic data were collected at the time of implant placement (T0), final prosthesis delivery (T1), 12 months following implant placement (T2), and 36 months after implant placement (T3). Results: At a 3 year follow up, the mean sub-crestal implant position change was -0.69mm (0.48) in the CX group and -0.16mm (0.22) (p<0.05). Another statistical significance emerged for the peri-implant mesial marginal mucosa position of the two groups over time. Mean values were 0.63mm (SD:1.43mm) for the CX group and 1.69mm (0.85) for the CV group. No statistically significant difference was found in recession between the CX and CV groups at all time points. Conclusion: A concave abutment configuration was associated with less bone remodeling. However, no difference was seen in the amount of recession between the two groups.
Disciplines
Dentistry
Keywords
Abutment; Concave; Convex; Design; Implant; Mucosa
Files
Download Full Text (2.5 MB)